Designed for professional applications, the DCA-2 is equipped with XLR-type input and output connections. Additionally, Channel A and B maximum gains can be adjusted ± 15 dB from the nominal unity gain of the system via recessed, front-panel controls. Maxi- mum cable length from the DCA-2 to the farthest remote is approximately 2,000 feet.
The Oxmoor system includes a number of unique features. A Preset control on the DCA-2 rear panel sets the degree of attenuation on power up, avoiding an unpredictable or unknown turn-on state. One or both channels can be switch-reset back to this “Preset” level at any time. Another rear panel control, labeled “Prior-ity,” sets a level to which the system can be temporarily forced by an external switch closure. Each RC-16 remote has terminals for preset and priority functions.The switch itself is not included.
The DCA-2T outputs are transformer balanced. Either system is capable of driving 600 ohm or higher imped- ance loads; maximum output is +18 dBm terminated, +20 dBu unterminated.